- 60 -
2. AllCall© Server Solution
3. AllCall© Client Solution.
For the Database and Server applications, you should see an icon
appear in the lower right corner of the desktop that looks like this:
The Software is now correctly installed and ready to program.
Programming the AllCall© Software
Once the SQL Database, Database Solution, Server Solution and
Client are running, you must program the software to reflect the customer’s
requirements. Therefore, this section will cover the various settings and
screens involved.
Note: for term definitions, please see the Appendices: Term Definitions
Zone Configuration Planning
One of the first things that must be asked about the facility is how
many zones will the facility require. What this means is that all of the bed &
bath calls, Pendants, Doors, Door bells etc. must be assembled in a list.
Any device which includes a wireless transmitter that must be learned in to
the panel is a Zone. This information can be found in the contract.
However, it is important to obtain a current floor plan to verify this figure. It
is very important to accurately determine this figure because each
control panel can only handle 96 zones.
Once this information is obtained from the facility, it should then be
compiled into a Zone list, that shows each panel, all of the zones that are
learned into it, what the names of each zone are (IE. 101 Bed A) and what
type of zone they are. (IE. Bed, Bath etc) This sheet will be of immense
importance when the software is programmed.
The software requires each zone to be assigned a unique number. (1,
2, 3, 4, etc.) How this sequence relates to room numbers and the physical